Article no.: 822600

Meter for measuring Dissolved Oxygen (D.O.).

Ergonomical probe that measures the amount of dissolved Oxygen by using Polarography, which is electro-chemical analysis by using low-current.
Manual calibration at two points: at 0 % Oxygen and at 100 % saturated air.

Before first use the probe must be filled with electrolyte, followed by calibration. Use Zero Oxygen calibration solution for the 0 % Oxygen calibration.

Included:
  • Milwaukee MW 600 Dissolved Oxygen Meter
  • Polarographic probe with 3 meter cable
  • Screwdriver for calibration
  • Membranes, 5 pcs
  • Elektrolyte solution, 30 ml
  • Battery 9 Vi
  • Instructions

The sample must be kept in movement during measuring, for example by moving the probe or by utilizing a magnetic stir plate. Depending on differences in altitude (relative to sea level) and salinity, the readout values may have to be corrected (correction tables included). Measuring during mashing can result in inconcistent values, due to chemical processes and naturally occuring anti-oxidants in the mash.
Automatic temperature compensation (ATC) between 0 °C and 30 °C.



Range: 0,0 to 19,9 mg/l
Resolution: 0,1 mg/l
Accuracy (at 25 °C): ± 1,5 %
Battery: 1 x 9V alcaline (included)
Dimensions: 145 x 80 x 40 mm (instrument), 163 x 33 mm (probe)
Weight: 220 g (instrument) 360 g (probe)

Instructions in English included.

In stock: 1

  • Fast delivery
  • International shipping
  • E-mail us, we reply swiftly!
  • BrandMilwaukee

Description

Article no.: 822600

Meter for measuring Dissolved Oxygen (D.O.).

Ergonomical probe that measures the amount of dissolved Oxygen by using Polarography, which is electro-chemical analysis by using low-current.
Manual calibration at two points: at 0 % Oxygen and at 100 % saturated air.

Before first use the probe must be filled with electrolyte, followed by calibration. Use Zero Oxygen calibration solution for the 0 % Oxygen calibration.

Included:
  • Milwaukee MW 600 Dissolved Oxygen Meter
  • Polarographic probe with 3 meter cable
  • Screwdriver for calibration
  • Membranes, 5 pcs
  • Elektrolyte solution, 30 ml
  • Battery 9 Vi
  • Instructions

The sample must be kept in movement during measuring, for example by moving the probe or by utilizing a magnetic stir plate. Depending on differences in altitude (relative to sea level) and salinity, the readout values may have to be corrected (correction tables included). Measuring during mashing can result in inconcistent values, due to chemical processes and naturally occuring anti-oxidants in the mash.
Automatic temperature compensation (ATC) between 0 °C and 30 °C.



Range: 0,0 to 19,9 mg/l
Resolution: 0,1 mg/l
Accuracy (at 25 °C): ± 1,5 %
Battery: 1 x 9V alcaline (included)
Dimensions: 145 x 80 x 40 mm (instrument), 163 x 33 mm (probe)
Weight: 220 g (instrument) 360 g (probe)

Instructions in English included.

Frågor och svar

Ställ en fråga
Frågor och svar (1)
Ställ en fråga
Frågor och svar (1)
Powered by TestFreaks
ICE2 Styrström
Hur lång sladd är med? Har behov av syremätning i kräftdamm och givarkabeln bör vara upp mot 3 meter för att kunna mäta vid bottnen där syrebrist lättast uppstår
Kundtjänst

Givarkabeln är ca 3 meter.